VEGABAR 86
Submersible pressure transmitter with ceramic measuring cell
With ceramic measuring cell
Application area
Your benefit
- Low maintenance costs thanks to wear-free ceramic measuring cell
- High plant availability through maximum overload and vacuum resistance of the ceramic measuring cell
- Self-cleaning effect through front-flush installation
Configure product
Product comparison
All documents and software for this product can be found in our Download Center.
Show all downloadsSubmersible pressure transmitter for level measurement of water, acids and alkalis
Specially optimized for measurement of water, alkalis, acids and other chemically aggressive liquids, the submersible pressure transmitter VEGABAR 86 with ceramic measuring cell finds application in a wide range of industries – from water level measurement in the wastewater sector to level measurement in the chemical industry or in food production.
The submersible pressure transmitter with ceramic measuring cell is ideal for:
- chemically stable level measurement in ultrapure water
- water level measurement with two suspension pressure transmitters for lock control
- Maintenace-free level measurement in waste water shafts
- 0 ... 25 bar [Bar - kPa - psi]
- -20 ... 100 °C [°C - °F]
- 0 ... 25 bar [Bar - kPa - psi]
- 0.1 %
- PVDF
- 316L
- FEP
- PE
- PUR
- ≥ G1½, ≥ 1½ NPT
- ≥ DN 40, ≥ 2"
- EPDM
- FKM
- FFKM
- Plastic
- Aluminium
- Stainless steel (precision casting)
- Stainless steel (electropolished)
- IP66/IP68 (0,2 bar)
- IP66/IP67
- IP66/IP68 (1 bar)
- IP66/IP68 (25 bar)
- IP69K
- Profibus PA
- Foundation Fieldbus
- 4 … 20 mA
- Two-wire: 4 … 20 mA/HART
- Modbus
- Secondary electronics for electronic differential pressure
- -40 ... 80 °C
- ATEX / Europe
- FM / USA
- EAC (GOST) / Belarus
- EAC (GOST) / Kazakhstan
- EAC (GOST) / Russia
- IEC / worldwide
- NEPSI / China
- UKR Sepro / Ukraine
- INMETRO / Brazil
- CCOE / India
- CSA / USA and Canada
- IA
- UKEX
- Intrinsic safety "i"
- Flameproof enclosure "d"
- Dust ignition protection "t"
- FDA
- Drinking water
- EG1935/2004
- ABS
- BV
- CCS
- DNV
- LR
- NK
- RINA
- WHG
- VLAREM II
- SIL2
- PLICSCOM
- PC, PACTware and DTM
- HART-Communicator
- Software (e. g. AMS™, PDM)
- Display/adjustment module PLICSCOM
- VEGADIS 81
- VEGADIS 82
Drawing generator
Generate 2D and 3D drawings for your specific configuration.
Configure NowProduct catalog
Hydrostatic
Product information
VEGABAR 86, 87, VEGAWELL 52
Specification sheet
VEGABAR 86
Two-wire: 4 … 20 mA
Operating instructions
VEGABAR 86
Two-wire: 4 … 20 mA
Drawing generator
Further downloads for this product
All documents and software for this product can be found in our Download Center.
Show all downloadsBluetooth USB adapter
![](/-/media/images/products/signal-conditioning/bluetooth-usb-adapter.png)
Wireless adjustment of sensors and instruments via Bluetooth
Show ProductVEGADIS 81
![](/-/media/images/products/signal-conditioning/f-dis81-messwertanzeige-bedienung-vega-sensoren-bt.png)
Remote measurement value indication and adjustment of plics® sensors
Show ProductVEGADIS 82
![](/-/media/images/products/signal-conditioning/f-dis82-messwertanzeige-bedienung-4-20ma-obt.png?rev=cdfa1c8d996d4b598f830b9a538bf8c5)
External measured value display and adjustment for 4 ... 20 mA/HART sensors
Show ProductVEGADIS 176
![](/-/media/images/products/signal-conditioning/vegadis176_digitales_anzeigeinstrument_ohne_hilfsenergie_für_schalttafeleinbau.png?rev=3da5ee1210bb4532b4471d344136740f)
Remote display for use in 4 ... 20 mA current loop
Show ProductMagnetic pen for display/adjustment module PLICSCOM
![PLICSCOM Magnet Pen](/-/media/images/products/accessory/f-102812-magnetpen.png?rev=32990f912edc4368a2e0da5b9582918f)
Magnetic pen for on-site adjustment
Show ProductVEGAMET 141
![](/-/media/images/products/signal-conditioning/f-met141-xxxx-display-v01/vegamet141-xxxx-display-variant.gif?mh=140&hash=B7C9C9B4329A881D5CC04BD751FDF5BD)
1 x 4 … 20 mA sensor input, 1 x 4 … 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
Show ProductVEGAMET 142
![](/-/media/images/products/signal-conditioning/f-met142-xxxx-display-v01/vegamet142-xxxx-display-variant.gif?mh=140&hash=6BFAB652B5111A6794F7442833F681A0)
2 x 4 … 20 mA sensor inputs, 2 x 4 … 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
Show ProductVEGAMET 341
![](/-/media/images/products/signal-conditioning/f-met341-xxxx-display-v01/vegamet341-xxxx-display-web.gif?mh=140&hash=4C5A06BC9481719600D7633C43988FC2)
1 x 4 … 20 mA sensor input, 1 x 4 … 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
Show ProductVEGAMET 342
![](/-/media/images/products/signal-conditioning/f-met342-xxxx-display-v01/vegamet342-xxxx-display-web.gif?mh=140&hash=FED44B915AC465997E44AC46D969E3F5)
2 x 4 … 20 mA sensor inputs, 2 x 4 … 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
Show ProductVEGAMET 841
![](/-/media/images/products/signal-conditioning/f-met841-xxx1c-with-display/vegamet841-xxxx-display-web.gif?mh=140&hash=02AC56F4FDCCFF8E0B39FD843A275FDD)
1 x 4 ... 20 mA sensor input, 1 x 4 ... 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 842
![](/-/media/images/products/signal-conditioning/f-met842-xxx1c-with-display/f-met842-xxx1c-with-display.gif?mh=140&hash=2497195F8F247D25BF7313B09303AB37)
2 x 4 ... 20 mA sensor inputs, 2 x 4 ... 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 861
![](/-/media/images/products/signal-conditioning/f-met861-xxx1c-with-display/f-met861-xxx1c-with-display.gif?mh=140&hash=FF343AE857941976F797AA6BE7C56287)
1 x 4 ... 20 mA/HART sensor input, 2 x digital inputs, 1 x 4 ... 20 mA current output, 4 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 862
![](/-/media/images/products/signal-conditioning/f-met862-xxx1c-with-display/f-met862-xxx1c-with-display.gif?mh=140&hash=AE5EB08BC41D5A93E617E43568D36080)
2 x 4 ... 20 mA/HART sensor inputs, 4 x digital inputs, 3 x 4 ... 20 mA current outputs, 6 x operating relays, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 624
![VEGAMET625 Auswertgeraet und Anzeigeinstrument fuer Fuellstandsensoren.png 352 KB VEGAMET624 Auswertgeraet und Anzeigeinstrument fuer Fuellstandsensoren](/-/media/images/products/signal-conditioning/f-vegamet624-auswertgeraet-und-anzeigeinstrument-fuer-fuellstandsensoren.png?rev=e518d2992e2d42249a775328c7c5a70b)
Measured value indication, simple control functions such as remote enquiry of measured values for a 4 ... 20 mA/HART sensor
Show ProductVEGAMET 625
![VEGAMET625 Auswertgeraet und Anzeigeinstrument fuer Fuellstandsensoren](/-/media/images/products/signal-conditioning/f-vegamet625-auswertgeraet-und-anzeigeinstrument-fuer-fuellstandsensoren.png?rev=47b21ad39956410cbb2462bb3f8109ef)
Measured value indication, simple control functions such as remote enquiry of measured values for two HART sensors
Show ProductVEGAMET 391
![VEGAMET391 Auswertgeraet und Anzeigeinstrument fuer Fuellstandsensoren](/-/media/images/products/signal-conditioning/f-vegamet391-auswertgeraet-und-anzeigeinstrument-fuer-fuellstandsensoren.png?rev=f3265eceecc4402fbe08a8bd43e2b62f)
Measured value indication, simple control functions, remote enquiry of measured data. optimized for water/sewage water industry
Show ProductVEGATOR 141
![Single channel signal conditioning instrument for level detection - 4 … 20 mA](/-/media/images/products/signal-conditioning/f-vegator141.png?rev=6e72c1df378346b391d1f14712a4ef76&mh=140&hash=10A72DC1892948224A4D25514C25A499)
Transmission of 4 ... 20 mA signals for level signalling
Show ProductVEGATOR 142
![Double channel signal conditioning instrument for level detection - 4 … 20 mA](/-/media/images/products/signal-conditioning/f-vegator142.png?rev=9d01b7d22ca5451fbfd347dab350b1ef&mh=140&hash=6A1876EFCA3CDEC6B5CEB44E4AB04C50)
Transmission of 4 ... 20 mA signals for level signalling
Show ProductVEGASCAN 693
![Signal conditioning instrument for up to 15 HART sensors](/-/media/images/products/signal-conditioning/f-vegascan693-auswertgeraet-fuer-bis-zu-15-hart-sensoren.png?rev=32d80a1365a34eb6b2a897bb57697a28)
Measured value indication and remote enquiry of measured data for up to 15 HART sensors
Show ProductPLICSMOBILE T81
![externe-GSM-GPRS-Funkeinheit](/-/media/images/products/signal-conditioning/f-plicsmobilet81-external-radio-unit-for-hart-sensors.png?rev=372f3249aeda4e12b7f390ee34e722dd)
Measured data enquiry and remote parameter adjustment for a HART sensor
Show ProductVEGATRENN 141
![Einkanaliger Speisetrenner für 4 … 20 m/HART-Sensoren](/-/media/images/products/signal-conditioning/f-vegatrenn141-1.png?rev=8d981222acb644d5bf77ec053f2b0808&mh=140&hash=C6A475A079EDE7E9E55E199875B8C504)
Single channel separator for 4 … 20 m/HART sensors
Show ProductVEGATRENN 142
![Zweikanaliger Speisetrenner für 4 … 20 m/HART-Sensoren](/-/media/images/products/signal-conditioning/f-vegatrenn142-1.png?rev=65ef1bf437dd49328031e5e7aee2d115&mh=140&hash=A1752D26495A20CB0378C775D87FFC6B)
Double channel separator for 4 … 20 m/HART sensors
Show ProductVEGATRENN 151
![Einkanaliger Trennübertrager in Zweileitertechnik für 4 … 20 mA-Sensoren](/-/media/images/products/signal-conditioning/f-vegatrenn151-1.png?rev=c071a5fc6a4a4b84a581c439b09c2be9&mh=140&hash=2E24CB4774F5EA97BCBE91AC2A760509)
Single channel separator in two-wire technology for 4 … 20 mA sensors
Show ProductVEGATRENN 152
![Zweikanaliger Trennübertrager in Zweileitertechnik für 4 … 20 mA-Sensoren](/-/media/images/products/signal-conditioning/f-vegatrenn152-1.png?rev=55aa7255fe3246e48aba34a39f4faf2f&mh=140&hash=94379E492874E14C39EF1D6434646FF1)
Double channel separator in two-wire technology for 4 … 20 mA sensors
Show ProductOvervoltage protection B 81-35
![](/-/media/images/products/signal-conditioning/overvoltagearrester-b81-35.png?rev=a2bd2cdf8a564ea59a7c95dc1ccf6af6)
Pluggable overvoltage protection for supply and signal cables
Show ProductOvervoltage protection B 63-32
![Überspannungsschutz B63](/-/media/images/products/signal-conditioning/f-ueberspannungsschutz-b63.png?rev=92ffca4f76234715a6d63d97214acba2)
Overvoltage protection for Profibus PA and Foundation Fieldbus circuits
Show ProductOvervoltage protection B 63-48
![Ueberspannungsschutz-B63](/-/media/images/products/signal-conditioning/f-ueberspannungsschutz-b63.png?rev=4fb859b6075e4dcb89ed3321364d574a)
Overvoltage protection for two-wire circuits
Show ProductOvervoltage protection B 62-30 W
![Ueberspannungsschutz B62-30W in Zweileitertechnik Profibus-PA Foundation-Fieldbus-Stromkreise](/-/media/images/products/signal-conditioning/f-ueberspannungsschutz-b62-30w-in-zweileitertechnik-profibus-pa-foundation-fieldbus-stromkreise.png?rev=1f13e070c76c43ceac5b887e13294186)
Overvoltage protection for Profibus PA and Foundation Fieldbus circuits
Show ProductOvervoltage protection B 62-36 G
![Ueberspannungsschutz B62-30G Versorgungs- und Signalleitungen in 4-20 mA-Stromkreisen](/-/media/images/products/signal-conditioning/f-ueberspannungsschutz-b62-30g-versorgungs-und-signalleitungen-in-4-20-ma-stromkreisen.png?rev=7e5c1e8ce85949ac8a5e5dad50e83909)
Overvoltage protection for two-wire circuits
Show ProductVEGACONNECT
![](/-/media/images/products/signal-conditioning/f-vegaconnect-interface-adapter.png?mh=140&hash=D421D3698C54B2193735254FA0BF45E3)
Interface adapter between PC and VEGA instruments
Show ProductVEGABOX 03
![Druckausgleichsgehäuse mit Belüftungsfilter](/-/media/images/products/signal-conditioning/f-box03-xxikxnxcx-v01.png?rev=0a024dfb91f44c17bf345758b309f4b5)
Breather housing with ventilation filter
Show ProductProfibus PA/DP segment coupler
![](/-/media/images/products/signal-conditioning/f-profibus-segment-coupler.png?rev=b4cd40c7aa2c43779edf7454faddb3a6)
Simple segment coupler for up to 93.75 kbit/s DP-side
Show ProductWelded socket with accessory VEGABAR series 80
![No image available](/-/media/images/noimage-available.png?rev=ca70c0d18334429e9e18ae4b6a12a93c)
Welded sockets are used to connect the sensors to the process.
Show ProductMeasuring instrument holder for wall/tube mounting
![No image available](/-/media/images/noimage-available.png?rev=ca70c0d18334429e9e18ae4b6a12a93c)
For mounting of pressure transmitters.
Show ProductMounting aid/Welding dummy
![No image available](/-/media/images/noimage-available.png?rev=ca70c0d18334429e9e18ae4b6a12a93c)
For mounting of pressure transmitters.
Show ProductAntenna extension PLICSMOBILE
VEGADIS adapter
![102410-Adapter-VEGADIS81-or-BAR-Slave](/-/media/images/products/accessory/102410-adapter-vegadis81-oder-bar-slave.png?rev=19cab4c6978d49dab2afbd9fce3b364e)
For connection of an external display and adjustment unit or a Secondary sensor.
Show ProductElectronics VEGABAR series 80
Process component VEGABAR 86
PLICSMOBILE plug connector with SMA connection
Electronics PLICSMOBILE series 80
An error has occurred
An error occurred when starting the configurator. We have documented the error and are working on it.
Please try again later. Alternatively you can contact us directly.
Thank you very much for your understanding.
VEGABAR 86
myVEGA - Your personal information platform
With myVEGA as your personal information platform, you’ll have at your disposal numerous online functions revolving around the VEGA products.
- Configurator for the entire VEGA product range
- Information about prices and delivery times
- Order directly online
- Saving of configurations
- 2D/3D drawings of your configured instrument
- Overview of order transactions
Still no access?
Register for freeForgot password
Enter your e-mail address and we will send you a link to reset your password.
Reset password Cancel
Close