Ammonia tank
Level measurement and point level detection in the ammonia tank
Process data
    Measuring task:
    
    Level measurement and point level detection
        Measuring point:
    
    Tank
        Measuring range up to:
    
    6 m
        Medium:
    
    Ammonia
        Process temperature:
    
    -40 … 0 °C
        Process pressure:
    
    +1 … +6 bar
        Special challenges:
    
    Extreme diffusion
Application
The diffusion behaviour of ammonia is extreme, which means it can eventually pass through any conventional process fitting or elastomer seal. To avoid any long term leaks and unwanted outages, gas-tight process sealing and special safety configurations are therefore mandatory, which considerably restricts the choice of instrumentation. The high risk potential and tough environmental restrictions also make reliable control of the level absolutely necessary when handling ammonia.
                    Your benefit
Reliable
                                Special sealing concept prevents diffusion
                            Cost effective
                                Maximum tank utilization
                            User friendly
                                Minimal maintenance costs
                            Recommended products
                                            VEGAFLEX 81
Level measurement with guided radar in the ammonia tank
- Measurement is unaffected by the ammonia atmosphere
 - Protection against ammonia diffusion using special sensor sealing concept
 - Precise measurement data enables high process reliability
 
Measuring range - Distance
                                                            75 m
                                                            Process temperature
                                                            -60 ... 200 °C
                                                            Process pressure
                                                            -1 ... 40 bar
                                                            
                                            VEGASWING 63
Vibrating level switch for overfill protection in the ammonia tank
- Absolutely diffusion-tight fully welded structure
 - Simple setup without calibration
 - Function test during operation reduces maintenance costs and increases process availability
 
Process temperature
                                                            -50 ... 250 °C
                                                            Process pressure
                                                            -1 ... 64 bar
                                                            Version
                                                            Standard
                                                                    Hygienic applications
                                                                    with gas-tight leadthrough
                                                                    with tube extension
                                                                    with temperature adapter
                                                            
                                    
                            
                                                    
                                            
Close