Gas pipeline
Flow meter for sludge gas
Process data
    Measuring task:
    
    Pressure
        Measuring point:
    
    Pipeline
        Measuring range up to:
    
    0 … 25 bar
        Medium:
    
    Biogas
        Process temperature:
    
    +5 … +100 °C
        Process pressure:
    
    -1 … +25 bar
        Special challenges:
    
    High resistance to chemicals
Application
The biogas generated from sewage sludge is used for environmentally friendly production of heat and electricity. It is transported to the storage tanks through a gas pipeline.
                    Your benefit
Reliable
                                Reliable monitoring of flow rate
                            Cost effective
                                Detailed information on the amount of gas produced
                            User friendly
                                Maintenance-free operation of the sensor technology
                            Recommended products
 
                                            VEGABAR 82
Monitoring of gas pressure 
- Sensor provides intrinsically safe output signal
- Meets the requirements of ATEX EEx ia IIC T6
- Maintenance-free operation through long-term stability of the ceramic measuring cell
Measuring range - Distance
                                                            -
                                                            Measuring range - Pressure
                                                            -1 ... 100 bar
                                                            Process temperature
                                                            -40 ... 150 °C
                                                             
                                            VEGATRENN 141
Separator for the optimum supply of power to the connected sensors
- On-site diagnostics for direct display of status via LEDs
- Simple parametrization interface using the HART sockets for user-friendly operation
- Galvanic separation of sensors and PLC is secured
Protection rating
                                                            IP20
                                                            Input
                                                            1 x 4 … 20 mA/HART sensor input
                                                            Output
                                                            1 x 4 … 20 mA
                                                             
                                            VEGADIF 85
Measurement of gas volume that is taken from the digester 
- Detection of the gas volume with standard orifice plate and differential pressure transmitter
- Simple adaptation to existing systems through different orifice plate dimensions
- Reliable measurement and maintenance-free operation
Measuring range - Pressure
                                                            -40 ... 40 bar
                                                            Process temperature
                                                            -90 ... 400 °C
                                                            Process pressure
                                                            -1 ... 400 bar
                                                             
                                    
                             
                                                    
                                            