Separation vessel
Level measurement and point level detection in a separator vessel tank for recovery of raw materials
Process data
    Measuring task:
    
    Level and interface measurement, point level detection
        Measuring point:
    
    Vessel
        Measuring range up to:
    
    15 m
        Medium:
    
    Water-based media and hydrocarbons
        Process temperature:
    
    +20 … +80 °C
        Process pressure:
    
    0 … +16 bar
        Special challenges:
    
    Alternating media properties, emulsions
Application
These processes often involve the separation of water-based media from hydrocarbons. In most applications, the upper, lighter medium is electrically non-conductive. Guided radar level measurement makes use of the effect that non-conductive media allow some of the radar energy to pass through, thus enabling a measurement of the interface between the water-based lower medium and the hydrocarbons.
                    Your benefit
Reliable
                                Reliable measurement of the interface (separation layer)
                            Cost effective
                                Maintenance-free operation
                            User friendly
                                Easy setup and commissioning
                            Recommended products
 
                                            VEGAFLEX 81
Level and interface measurement with guided radar in the separation tank
- Total level and position of the interface are reliably detected with a rod or coaxial sensor
- Separation layer thicknesses from 50 mm can be measured
- VEGAFLEX 81 measures reliably and accurately, even in emulsion phases
- Simple setup and maintenance-free operation
Measuring range - Distance
                                                            75 m
                                                            Process temperature
                                                            -60 ... 200 °C
                                                            Process pressure
                                                            -1 ... 40 bar
                                                             
                                            VEGACAP 63
Capacitive level switch for conductive liquids for level measurement in the separation tank
- Reliable differentiation between conductive and non-conductive media
- Reliable level measurement of the separated water quantity for disposal
- Simple mounting and calibration
Measuring range - Distance
                                                            -
                                                            Process temperature
                                                            -50 ... 200 °C
                                                            Process pressure
                                                            -1 ... 64 bar
                                                             
                                    
                             
                                                    
                                            