Inlet channel
Flow-rate measurement in open channels
Process data
    Measuring task:
    
    Flow measurement
        Measuring point:
    
    Flume
        Measuring range up to:
    
    0 … 1 m
        Medium:
    
    Wastewater
        Process temperature:
    
    0 ... +40 °C
        Process pressure:
    
    0 … 0 bar
        Special challenges:
    
    Condensation, fog, wind, solar radiation
Application
Sewage and rainwater are often transported to the treatment plant in open collection channels or flumes. The flow rate is measured at various points in these channels. Measurement of the water flow at the inlet and outlet of the treatment plant is the basis for the calculation of tariffs and operating costs.
                    Your benefit
Reliable
                                High measurement accuracy, independent of temperature influence
                            Cost effective
                                Low maintenance requirements
                            User friendly
                                Flow-proportional output signal
                            Recommended products
 
                                            VEGAPULS C 21
Flow measurement of the wastewater inlet with radar in an open channel
- High plant availability thanks to wear and maintenance free measurement
- Exact measuring results unaffected by ambient conditions.
- Sensor-integrated flow characteristic curves make it also possible to have a direct flow-proportional output signal
- Secure wireless operation through Bluetooth with smartphone, tablet or PC
Measuring range - Distance
                                                            20 m
                                                            Process temperature
                                                            -40 ... 80 °C
                                                            Process pressure
                                                            -1 ... 3 bar
                                                             
                                            VEGAMET 861
Flow computation, control and display for open channel flow measurement structures
- Highly accurate calculation of the flow rate
- Clear, simple display of flow rate and total flow volume
- Fast setup and commissioning thanks to simple menu navigation and application wizards
Protection rating
                                                            IP66/IP67, Type 4X
                                                            Input
                                                            1 x 4 … 20 mA/HART sensor input
                                                                    2x digital input
                                                            Output
                                                            1 x 0/4 … 20 mA current output
                                                                    1x failure relay (instead of operating relay)
                                                                    4x operating relay
                                                            Do radar sensors also measure even at changing temperatures?
                    We need your consentThis content is provided by an external provider. If you activate the content, personal data may be processed and cookies set.
                
                     
            Blog Articles
 
                     
                                    
                             
                                                    
                                            
Close