Lime silo
Level measurement and high level detection in the lime silo
Process data
    Measuring task:
    
    Level measurement and point level detection
        Measuring point:
    
    Silo
        Measuring range up to:
    
    0 … 8 m
        Medium:
    
    Lime
        Process temperature:
    
    0 ... +30 °C
        Process pressure:
    
    1 … 3 bar
        Special challenges:
    
    Abrasion, caked deposits, silo internals
Application
In the nitrogen and phosphorus removal stage, lime is used to stabilize the pH value. Stored in silos, the lime is added to the wastewater as a solid or as an aqueous suspension. The silo content is measured by a radar sensor and a point level sensor detects the maximum level and transmits a full signal.
                    Your benefit
Reliable
                                Certain measurement even during filling
                            Cost effective
                                Reliable measurement of the total material volume in the silo 
                            User friendly
                                Simple installation and setup
                            Recommended products
 
                                            VEGAPULS C 23
Non-contact level measurement with radar in the lime silo
- Maintenance-free operation thanks to non-contact measuring method
- Reliable measurement despite strong dust generation and buildup on the sensor
- Very good focusing allows exact measurement even with material deposits on the silo walls
Measuring range - Distance
                                                            30 m
                                                            Process temperature
                                                            -40 ... 80 °C
                                                            Process pressure
                                                            -1 ... 3 bar
                                                             
                                            VEGACAP 65
Point level detection for full signal during filling 
- Point level detection for reliable high level alarm during filling
- Mechanically robust sensor version guarantees long service life
- cable length shortened for easy adaptation to vessel size
Measuring range - Distance
                                                            -
                                                            Process temperature
                                                            -50 ... 200 °C
                                                            Process pressure
                                                            -1 ... 64 bar
                                                             
                                            VEGATOR 141
Double channel signal conditioning instrument for level detection
- Simple adjustment of the switching point through a potentiometer
- Clearly visible switching status via LED
- Simple installation through carrier rail mounting as well as detachable, coded terminals
Protection rating
                                                            IP20
                                                            Input
                                                            1 x 4 … 20 mA sensor input
                                                            Output
                                                            1 x operating relay (SPDT)
                                                                    Optionally 1 x fail safe relay output (SPDT)
                                                             
                                    
                             
                                                    
                                            
Close