Interface profiler
Multi-phase oil/water interface measurement in separator tanks with emulsion layers
Process data
    Measuring task:
    
    Level and density measurement
        Measuring point:
    
    Tank
        Measuring range up to:
    
    4 m
        Medium:
    
    Mixture of oil, water, emulsions and sand
        Process temperature:
    
    -40 … +150 °C
        Process pressure:
    
    -1 … +120 bar
        Special challenges:
    
    Low dielectric constant of the medium, buildup
Application
Separation tanks on the deck of an FPSOs contain oil and water as well as other products. Mixing hydrocarbons with water can form an emulsified layer that makes it extremely difficult for operators to detect and control the water level. This can lead to loss of hydrocarbons when the water is drained or even damage to the electrostatic grids in desalination tanks due to the salty feed water. Multi phase density profiling is required to identify the different layers, including sand, for reliable, efficient process control. Level measurement is also required to ensure redundancy.
                    Your benefit
Reliable
                                External detectors provide a high-resolution density profile without being exposed to process conditions
                            Cost effective
                                No shutdown required for maintenance
                            User friendly
                                Standard instruments without PLC or special tools
                            Recommended products
 
                                            VEGAFLEX 86
Level and interface measurement in the bypass
- High accuracy of the level in an external bypass chamber
- Shortenable rod probe allows great flexibility in project planning
- Reliable measurement, independent of process density, temperature and pressure
Measuring range - Distance
                                                            75 m
                                                            Process temperature
                                                            -196 ... 450 °C
                                                            Process pressure
                                                            -1 ... 400 bar
                                                             
                                            VEGAPULS 6X
Level measurement with radar through isolation valve in the interface profiler.
- High-precision measurement independent of pressure, temperature or density
- SIL conformity according to IEC 61511 for functional safety
- High dynamic range independent of dielectric constant, foam or varying hydrocarbons
Measuring range - Distance
                                                            120 m
                                                            Process temperature
                                                            -196 ... 450 °C
                                                            Process pressure
                                                            -1 ... 160 bar
                                                             
                                            MINITRAC 31
Radiometric multiphase interface measurement in oil separators
- High-resolution density measurement with scintillation detectors that can detect the smallest changes in radiation absorption by different media
- Maintenance-free and accessible, as the sensors are installed outside the vessels
Measuring range - Distance
                                                            -
                                                            Process temperature
                                                            -40 ... 60 °C
                                                            Process pressure
                                                            -
                                                             
                    
Close