VEGAPULS 63
Radar sensor for continuous level measurement of liquids
For aggressive liquids or under hygienic requirements
Application area
Your benefit
- Exact measuring results independent of process conditions
- High plant availability, because wear and maintenance-free
- Maintenance-free operation through non-contact measuring principle
 
                Newer product available
There is a successor for this product. If you have any questions about the product, please contact your VEGA representative.
VEGAPULS 6XConfigure product
Configure productProduct comparison
All documents and software for this product can be found in our Download Center.
Show all downloadsLevel measurement of aggressive liquids under difficult process conditions – especially hygienic and chemically stable
 
                    - 35 m [Meter - Foot]
- -196 ... 200 °C [°C - °F]
- -1 ... 16 bar [Bar - kPa - psi]
- ± 2 mm
- 26 GHz
- ≥ 10°
- hygienically encapsulated horn antenna
- PFA
- PTFE
- 316L
- TFM-PCTFE
- TFM-PTFE
- ≥ DN50, ≥ 2"
- Clamp ≥ 2", DN50 - DIN32676, ISO2852
- Slotted nut ≥ 2", DN50 - DIN 11851
- Varivent ≥ DN25
- hygienic fitting with tension flange DN32
- hygienic fitting F40 with compression nut
- Hygienic screw connections ≥ DN50 tube ø53 - DIN11864-1-A
- Hygienice flange connection ≥ DN50 DIN11864-2
- Hygienic clamp connection ≥ DN50 pipe Ø53 - DIN11864-3-A
- DRD connection ø 65 mm
- SMS 1145 DN51
- Plastic
- Aluminium
- Stainless steel (precision casting)
- Stainless steel (electropolished)
- IP66/IP68 (0,2 bar)
- IP66/IP67
- IP66/IP68 (1 bar)
- Profibus PA
- Foundation Fieldbus
- Two-wire: 4 … 20 mA/HART
- Modbus
- Four-wire: 4 … 20 mA/HART
- -40 ... 80 °C
- ATEX / Europe
- CSA / Canada
- FM / USA
- EAC (GOST) / Belarus
- EAC (GOST) / Kazakhstan
- EAC (GOST) / Russia
- IEC / worldwide
- KOSHA / Korea
- NEPSI / China
- UKR Sepro / Ukraine
- IEC / Australia
- UKEX
- Intrinsic safety "i"
- Flameproof enclosure "d"
- Dust ignition protection "t"
- 3A
- EHEDG
- FDA
- ABS
- BV
- CCS
- DNV
- GL
- LR
- NK
- RINA
- RMROS
- WHG
- SIL2
- PLICSCOM
- PC, PACTware and DTM
- HART-Communicator
- Software (e. g. AMS™, PDM)
- Display/adjustment module PLICSCOM
- VEGADIS 81
- VEGADIS 82
Drawing generator
Generate 2D and 3D drawings for your specific configuration.
Configure NowDirect downloads
Product information
VEGAPULS WL 61, 61, 62, 63, 64, 65, 66
Specification sheet
VEGAPULS 63
Two-wire: 4 … 20 mA/HART
Operating instructions
VEGAPULS 63
Two-wire: 4 … 20 mA/HART
Supplementary instructions
Connection cable
Additional links
Drawing generator
Generate 2D and 3D drawings for your specific configuration.
Configure NowFurther downloads for this product
All documents and software for this product can be found in our Download Center.
Show all downloadsBluetooth USB adapter
 
                                                                            Wireless adjustment of sensors and instruments via Bluetooth
Show ProductVEGADIS 81
 
                                                                            Remote measurement value indication and adjustment of plics® sensors
Show ProductVEGADIS 82
 
                                                                            External measured value display and adjustment for 4 ... 20 mA/HART sensors
Show ProductVEGADIS 176
 
                                                                            Remote display for use in 4 ... 20 mA current loop
Show ProductMagnetic pen for display/adjustment module PLICSCOM
 
                                                                            Magnetic pen for on-site adjustment
Show ProductVEGAMET 141
 
                                                                            1 x 4 … 20 mA sensor input, 1 x 4 … 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
Show ProductVEGAMET 142
 
                                                                            2 x 4 … 20 mA sensor inputs, 2 x 4 … 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
Show ProductVEGAMET 341
 
                                                                            1 x 4 … 20 mA sensor input, 1 x 4 … 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
Show ProductVEGAMET 342
 
                                                                            2 x 4 … 20 mA sensor inputs, 2 x 4 … 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
Show ProductVEGAMET 841
 
                                                                            1 x 4 ... 20 mA sensor input, 1 x 4 ... 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 842
 
                                                                            2 x 4 ... 20 mA sensor inputs, 2 x 4 ... 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 861
 
                                                                            1 x 4 ... 20 mA/HART sensor input, 2 x digital inputs, 1 x 4 ... 20 mA current output, 4 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 862
 
                                                                            2 x 4 ... 20 mA/HART sensor inputs, 4 x digital inputs, 3 x 4 ... 20 mA current outputs, 6 x operating relays, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 624
 
                                                                            Measured value indication, simple control functions such as remote enquiry of measured values for a 4 ... 20 mA/HART sensor
Show ProductVEGAMET 625
 
                                                                            Measured value indication, simple control functions such as remote enquiry of measured values for two HART sensors
Show ProductVEGAMET 391
 
                                                                            Measured value indication, simple control functions, remote enquiry of measured data. optimized for water/sewage water industry
Show ProductVEGATOR 141
 
                                                                            Transmission of 4 ... 20 mA signals for level signalling
Show ProductVEGATOR 142
 
                                                                            Transmission of 4 ... 20 mA signals for level signalling
Show ProductVEGASCAN 693
 
                                                                            Measured value indication and remote enquiry of measured data for up to 15 HART sensors
Show ProductPLICSMOBILE T81
 
                                                                            Measured data enquiry and remote parameter adjustment for a HART sensor
Show ProductVEGATRENN 141
 
                                                                            Single channel separator for 4 … 20 m/HART sensors
Show ProductVEGATRENN 142
 
                                                                            Double channel separator for 4 … 20 m/HART sensors
Show ProductVEGATRENN 151
 
                                                                            Single channel separator in two-wire technology for 4 … 20 mA sensors
Show ProductVEGATRENN 152
 
                                                                            Double channel separator in two-wire technology for 4 … 20 mA sensors
Show ProductOvervoltage protection B 81-35
 
                                                                            Pluggable overvoltage protection for supply and signal cables
Show ProductOvervoltage protection B 63-32
 
                                                                            Overvoltage protection for Profibus PA and Foundation Fieldbus circuits
Show ProductOvervoltage protection B 63-48
 
                                                                            Overvoltage protection for two-wire circuits
Show ProductOvervoltage protection B 62-30 W
 
                                                                            Overvoltage protection for Profibus PA and Foundation Fieldbus circuits
Show ProductOvervoltage protection B 62-36 G
 
                                                                            Overvoltage protection for two-wire circuits
Show ProductVEGACONNECT
 
                                                                            Interface adapter between PC and VEGA instruments
Show ProductVEGABOX 03
 
                                                                            Breather housing with ventilation filter
Show ProductProfibus PA/DP segment coupler
 
                                                                            Simple segment coupler for up to 93.75 kbit/s DP-side
Show ProductElectronics VEGAPULS series 60 plics®plus
Electronics VEGAPULS series 60 plics®
Process component VEGAPULS 63
An error has occurred
An error occurred when starting the configurator. We have documented the error and are working on it.
Please try again later. Alternatively you can contact us directly.
Thank you very much for your understanding.
VEGAPULS 63
myVEGA - Your personal information platform
With myVEGA as your personal information platform, you’ll have at your disposal numerous online functions revolving around the VEGA products.
- Configurator for the entire VEGA product range
- Information about prices and delivery times
- Order directly online
- Saving of configurations
- 2D/3D drawings of your configured instrument
- Overview of order transactions
Still no access?
Register for freeForgot password
Enter your e-mail address and we will send you a link to reset your password.
Reset password Cancel
 
                         
                         
                         
             
             
            
 
                 
                 
                 
                 
                 
                 
                 
                 
                 
                 
                 
                 
                 
                 
                 
                 
                 
                                                                             
                                                                             
                                                                             
                                                                            
Close